Which are the advantages of the digital Master-Slave function?

With these models the switching threshold can be set up automatically via the push of a button. If you don’t require the master-slave function at the moment, you can activate the permanent mode for the slave sockets if desired. The power strip will then ignore the master-slave function. The stored switching threshold, or rather the permanent mode, will also remain if the master-slave power strip is temporarily turned off by the main switch.

Dlaczego mój automatyczny przedłużacz listwowy przestał wyłączać gniazda wtykowe „slave”?

U niektórych klientów zdarza się, że gniazda wtykowe „slave” nie są wyłączane, mimo że urządzenie „master” jest wyłączone. Przyczyną mogą być bardzo wysokie prądy włączeniowe podłączonych urządzeń „slave”, które znacząco przekraczają maks. obciążalność przekaźnika, powodując zgrzewanie styków na skutek wysokiej temperatury. W wielu przypadkach styki dają się ponownie rozłączyć na skutek wstrząsów (pukania), dzięki czemu będą jeszcze działać przez jakiś czas. Jednakże bez zmiany w konfiguracji urządzeń „slave” problem z reguły szybko powraca.  

Przyczyny:

Nasze automatyczne przedłużacze listwowe i stosowane w nich przekaźniki są zasadniczo przystosowane do obciążenia stałego prądami 16A. Urządzenia końcowe z wtyczką ze stykiem ochronnym typu Schuko nie mogą przyjąć większego prądu. W rzeczywistości jednak niektóre z urządzeń końcowych przekraczają wielokrotnie daną wartość graniczną w momencie włączenia. Pobór prądu może na ułamek sekundy wzrosnąć np. do wartości 50A lub wyższej. Wysokie prądy mogą powodować zgrzewanie styków w przekaźniku – w konsekwencji przekaźnik przestanie się wyłączać. Z doświadczenia wiadomo, że problem ten pojawia się częściej w przypadku urządzeń końcowych z zasilaczami impulsowymi. W dzisiejszych czasach mogą być one zainstalowane praktycznie wszędzie, np. w komputerze, monitorze, drukarce, zewnętrznych dyskach twardych, aktywnych głośnikach... Które konkretnie produkty stanowią potencjalne źródło tego rodzaju problemów zależy od tego, czy producenci urządzeń końcowych zastosowali odpowiednie rozwiązania przeciwdziałające zbyt wysokim prądom włączeniowym czy też nie. Niestety nie da się tego odczytać ani z karty charakterystyki ani z tabliczki znamionowej. Mając powyższe na uwadze, dokonaliśmy optymalizacji naszych automatycznych przedłużaczy listwowych, stosując specjalne przekaźniki dla obciążeń impulsowych o maks. wartości 80A. Dzięki temu problem występuje znacznie rzadziej.

What can I use an automatic Master-Slave power strip for?

The power switch of a single device plugged into the master socket will automatically shut on and off all other devices plugged into the slave sockets. For example, you can use a computer as a master device, and a printer, monitor, modem and so on as slave devices incorporated into the automatic control. Of course you can also use such combinations as TV, radio, receiver, and so on.

How do I set up the switching threshold at an automatic power strip with control?

1. Place your master device in the master socket and switch it on. 2. Slowly and carefully turn the control of the switching threshold until you find a position in which the slave socket will be turned on and off. Note this as control position 1. (for users with higher power consumption leave the slave socket on). 3. Turn the master device off again, but let it remain plugged in. 4. Slowly and carefully turn the control of the switch until you find a position in which the slave socket will be truned on and off. Note this as control position 2. (for users with or without lower standby-power consumption the slave sockets stay turned on at all times). 5. Adjust the control in the centre between control position 1 and control position 2. (if you cannot find control position one or two adjust the control in the centre between the controller stops).

How do I set up the switching threshold at an automatic power strip with control?

How do I set up the switching threshold on an automatic power strip with a digital master-slave function?

These devices feature an automatic switching threshold setting, which is activated by pressing a button: 1. Turn on the automatic power strip at the main switch. 2. Insert the master device into the master socket. 3. Switch the master device into the standby mode or turn it off completely, if it is not already. 4. Press and hold the button Learn” on the automatic power strip for approx. 3 sec., until the “Slave on” lamp begins to blink. 5. The lamp “Slave on blinks only for a short time. During this time the standby power consumption of the master device will automatically ascertain and store the switching threshold. 6. If the lamp “Slave on” stops blinking, the setup procedure is finished. The automatic switch function can now be used.

How do I set up the switching threshold on an automatic power strip with a digital master-slave function?

Permanent mode with an automatic power strip with digital master-slave function.

To activate permanent mode: • Proceed as with the automatic switching threshold adjustment. • While the “slave on” light is blinking (step 5), press the button “learn” again for 3 sec. The automatic switching threshold adjustment will be finished and the permanent mode for the slave socket will be activated. To deactivate permanent mode: • Perform the automatic switching threshold adjustment again.