Company Quality

Key to cable quality

Kabelqualitäten




 

 

Definition
H - Harmonised cable
A - Other nationally cable

Nominale Voltage (Volt)
03 - 300 / 300 V
05 - 300 / 500 V
07 - 450 / 750 V

Isolating Sheath
V - PVC
V3 - PVC, cold-resistant to -35°C
R - Natural or synthetic rubber
S - Silicone rubber
B - Synthetic rubber

Outher Sheath
V - PVC
V3 - PVC cold-resistant to -35°C
R - Natural or synthetic rubber
N - Neoprene 
J - Glass fibre
T - Textile
Q - Polyurethane
 

Cable Type
U
- Round, single-wire cable
R - Round, multi-wire cable
K - Fine wire for permanent installation
F - Fine wire for moveable cables
H - Extremely fine wire for moveable cables
Y - Tinsel wire

Number of Wires

Protected cables
G - With green-yellow wire
X - Without green-yellow wire

Diameter of Cable Core
in mm²

Special shapes/cable name extensions
AT - Country-specific standard for Austria
K35 - Cold-resistant to -35 °C

The right cable for every use

 

Kabelqualitäten Kabelqualitäten

For long-term outside use.
Withstands high mechanical loads and resists abrasion. Resistant to weather, microbes and acid. Cold-resistant to -40 °C. Polyurethane outer sleeve.

 

Kabelqualitäten Kabelqualitäten

For long-term outside use.
Resistant against oils and acids. Inner wire coating made of natural or synthetic rubber. Outer cable casing made of neoprene.

 

Kabelqualitäten Kabelqualitäten


N07: For outside use.
N05: For temporary outside use.

Oil resistant. High mechanical loading capacity. Anti-freezing, remains highly flexible down to -35°C. Outer cable casing made of highly flexible special plastic.

 

Kabelqualitäten

Standard version for normal use in dry conditions and for temporary outside use.
Inner wire coating and outer cable casing made of synthetic rubber. For temporary outside use.

 

Kabelqualitäten

Standard version for normal use in dry conditions.
With insulated inner wire coating and outher cable casing made of flexible PVC.