FAQ
Prosím, zvolte
Master-Slave is now Main-Follow - the function is the same!
Master-Slave is now Main-Follow - the function is the same! If the device connected in the Main-socket is switched on, all units in the Follow-sockets are automatically activated.
When no more current flows through the Main-socket, the Follow-sockets are automatically switched off.
Why does the Main-Follow function not work properly with laptops?
The Main-Follow function is based on a measurement of the current consumption at the main socket.
If the measurement is above the set threshold, the follow sockets are automatically switched on.
If the measurement is below the set threshold, the follow sockets are automatically switched off.
With battery-operated devices such as laptops, however, the current consumption does not necessarily correspond to the operating state on or off.
The current consumption can also be above the threshold value (charge battery) when the laptop is switched off or below the threshold value when the laptop is switched on. or below the threshold value when the laptop is switched on (battery full and laptop operating at low power).
The use of battery-operated devices as masters is therefore generally unsuitable.
Which are the advantages of the digital Main-Follow function?
With these models the switching threshold can be set up automatically via the push of a button. If you don’t require the Main-Follow function at the moment, you can activate the permanent mode for the follow sockets if desired. The extension lead will then ignore the Main-Follow function. The stored switching threshold, or rather the permanent mode, will also remain if the Main-Follow extension lead is temporarily turned off by the main switch.
Proč moje automatická napájecí lišta přestala vypínat zásuvky Follow?
Někteří uživatelé zjistili, že následné zásuvky se již nevypínají, i když je hlavní jednotka vypnutá. To může být způsobeno velmi vysokými rozběhovými proudy připojených následných jednotek, které výrazně překračují maximální zatížitelnost relé, a tím zavařují spínací kontakty.
V mnoha případech lze spínací kontakty od sebe opět oddělit vibracemi (klepáním) a dočasně je tak uvést do funkce. Bez změny konfigurace sledovacích jednotek se však problém obvykle rychle objeví znovu.
Souvislosti:
Naše automatické zásuvkové lišty jako celek a relé v nich použitá jsou navrženy pro trvalé zatížení proudem 16 A. Koncová zařízení s ochrannou kontaktní zástrčkou nesmějí odebírat větší proud. Některá koncová zařízení však tento limit v okamžiku zapnutí mnohonásobně překračují. Odběr proudu může na zlomek sekundy vzrůst na 50 A nebo více. Tyto vysoké proudy mohou způsobit zavaření spínacích kontaktů relé - relé pak již nevypíná.
Zkušenosti ukazují, že tento problém se častěji vyskytuje u terminálů se spínanými zdroji napájení. Ty lze dnes instalovat téměř všude, např. do počítače, monitoru, tiskárny, externích pevných disků, aktivních reproduktorů atd. Které výrobky takové problémy skutečně způsobují, závisí také na tom, zda výrobci koncových zařízení přijali vhodná opatření proti nadměrným rozběhovým proudům. To bohužel nelze vyčíst z žádného datového listu nebo typového štítku. Naše automatické zásuvkové lišty jsme v tomto ohledu optimalizovali použitím speciálních relé pro impulzní zatížení až 80 A. Problém se proto vyskytuje mnohem méně často.
What can I use an automatic extension lead with Main-Follow function for?
With the on/off switch of a single device plugged into the main socket, all other devices in the follow sockets can be switched on and off automatically. You can use a computer as the main device, for example, which includes monitors, printers, modems, etc. as follow devices in the automatic control. Of course, combinations of TV, radio, receiver, etc. can also be controlled.
How do I set the switching threshold on an automatic extension lead with setting controller?
1. Plug your main unit into the red main socket and switch it on.
2. Turn the switching threshold control slowly and carefully until you find a position where the follow sockets are switched on and off. Make a note of this control position 1 (the follow sockets always remain on for consumers with high current consumption).
3. Now switch off your main unit again, but leave it plugged in.
4. Turn the switching threshold control slowly and carefully until you find a position at which the follow sockets are switched on and off. Make a note of this control position 2 (for consumers without or with low standby current consumption, the follow sockets always remain off).
5. Now place the setting control centrally between control position 1 and control position 2. (In cases where you could not determine control positions 1 or 2, please place the setting control centrally between the control stops).
How do I set the switching threshold on an automatic extension with digital Main-Follow function?
These devices have an automatic switching threshold setting that is started by pressing a button.
1. Switch on the automatic extension lead at the main switch.
2. Plug the main unit into the red main socket.
3. Put the main unit in standby mode or switched off mode, if this is not already the case.
4. Press and hold the "Learn" button on the automatic extension lead for approx. 3 seconds until the "Follow on" lamp starts to flash.
5. The "Follow on" lamp now flashes for a short time. During this time, the standby power consumption of the main unit is automatically determined and the switching threshold is saved.
6. When the "Follow on" lamp stops flashing, the setting process is finished. The automatic switching function can now be used.
Permanent mode with an automatic extension lead with digital Main-Follow function
Activation of the permanent mode:
- Proceed in the same way as for the automatic switching threshold setting.
- While the "Follow on" lamp is flashing (point 5), press the "Learn" button again for approx. 3 sec. The automatic switching threshold setting is terminated and the permanent mode for the follow sockets is activated.
Deactivating the permanent mode:
- Simply perform an automatic switching threshold setting again.